We Don't Stop at Delivery.
Manufacturing a transformer is where our responsibility begins — not where it ends. KLR Transformers provides the full range of field services needed to keep transformers of any make operating reliably across their entire working life.
Any make · Any capacity · Any location across India
Structured, scheduled maintenance programmes that keep critical transformers inspected, tested, and documented — reducing the risk of unplanned failure and extending operational life.
✓ Scheduled site visits 1, 2, or 4 per year to requirement
✓ Oil sampling and BDV testing
✓ Insulation resistance (IR) and winding resistance measurement
✓ Thermographic inspection thermal imaging for hot-spot detection
✓ Silica gel breather inspection and replacement
✓ Buchholz relay, pressure relief, and gauge checks
✓ Maintenance history log maintained per unit
✓ Priority emergency response for AMC contract holders
Transformer oil degrades over time through moisture absorption, oxidation, and particle contamination. Our mobile oil filtration service restores dielectric strength on-site — without removing the transformer from service.
✓ Hot oil circulation filtration removes moisture and particles
✓ Vacuum oil filtration moisture extraction under vacuum
✓ BDV improvement raising breakdown voltage to target specification
✓ Oil moisture content measurement before and after treatment
✓ Oil acidity and dissolved gas analysis (DGA) sampling
✓ Top-up with treated, tested oil to correct level
✓ Treatment report issued with before/after BDV readings
Factory-trained engineers deployed to site for fault diagnosis, repair, and restoration of transformers of any make and any capacity — with fast response and comprehensive on-site capability.
✓ Fault diagnosis and root cause analysis
✓ Bushing replacement LV and HV, all types
✓ Gasket replacement and oil leak repair
✓ Tap changer inspection, adjustment, and repair
✓ On-site winding repair where structurally feasible
✓ Oil filtration and top-up as part of repair scope
✓ Post-repair testing IR, BDV, ratio, and polarity checks
✓ Commissioning support after repair completion
When a transformer’s performance degrades below acceptable levels, full reconditioning restores it to near-original specification — extending operational life significantly at a fraction of new unit replacement cost.
✓ Full disassembly, inspection, and condition assessment
✓ Core inspection lamination integrity and joint condition
✓ Winding assessment resistance, IR, and turns ratio measurement
✓ Rewinding where conductor or insulation is beyond repair
✓ Insulation refurbishment paper and pressboard replacement
✓ Tank and radiator rehabilitation cleaning, repainting, leak repair
✓ Vapour Phase Drying (VPD) after rewinding
✓ Vacuum oil filling with fresh, tested transformer oil
✓ Complete retesting to original specification parameters
✓ Reconditioned unit report with before/after performance data
Independent testing and commissioning services for transformers of all makes — verifying performance before energisation, after repair, and as part of regular condition monitoring programmes.
✓ Pre-commissioning testing new units before first energisation
✓ Post-repair acceptance testing after service or repair
✓ Routine condition-based testing IR, BDV, winding resistance
✓ Voltage ratio and polarity verification
✓ On-load tap changer (OLTC) performance testing
✓ Dissolved gas analysis (DGA) incipient fault detection
✓ Partial discharge (PD) measurement available on request
✓ Compliance testing BIS, IEC, and ANSI standards as required
✓ Third-party witnessed testing certified inspector attendance
✓ Test report issued with all measurements and pass/fail status
Critical spare parts for KLR-manufactured transformers and compatible replacements for other makes — reducing lead times for planned maintenance and emergency repair.
✓ HV and LV bushings porcelain and oil-filled types
✓ Tap changers OLTC and OCTC types, major brands
✓ Buchholz relays and pressure relief devices
✓ Winding temperature indicators (WTI) and oil temperature indicators (OTI)
✓ Conservator tanks and drain valves
✓ Radiators and cooling fans
✓ Gaskets and sealing sets all flange sizes
✓ Transformer oil new and reclaimed, tested stock
✓ Silica gel breathers and oil level indicators
✓ Available for KLR units and third-party makes on enquiry